REACH substance testing is the laboratory process of identifying and quantifying Substances of Very High Concern (SVHC) and Annex XVII restricted substances in materials and finished articles intended for the EU market under Regulation (EC) No 1907/2006. This technical guide explains the scope of REACH substance determination, applicable sample types, common testing items and regulatory limits, standard analytical methods such as GC-MS and ICP-MS, and practical compliance considerations for manufacturers and importers.
Technical Overview
REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is Regulation (EC) No 1907/2006 of the European Parliament and of the Council, administered by the European Chemicals Agency (ECHA). It governs chemical substances on their own, in mixtures, and in articles placed on the EU market, and it is one of the most far-reaching chemical compliance frameworks in global trade.
REACH substance determination refers to the analytical testing of raw materials, components, and finished articles to quantify Substances of Very High Concern (SVHC) included on the Candidate List and substances restricted under Annex XVII of the regulation. Testing provides the objective evidence needed to fulfil several legal obligations:
- Article 33 communication duty: supplying information when an article contains an SVHC above 0.1% weight-by-weight (w/w), including responses to consumer requests within 45 days.
- SCIP notification: submitting information on articles containing SVHCs above 0.1% w/w to the ECHA SCIP database under the Waste Framework Directive.
- Annex XVII restriction compliance: ensuring restricted substances do not exceed applicable concentration or release limits.
- Annex XIV authorisation awareness: managing substances on the Authorisation List within sunset-date deadlines.
Substances are identified as SVHC under Article 57 when they are carcinogenic, mutagenic, or toxic to reproduction (CMR, category 1A or 1B); persistent, bioaccumulative, and toxic (PBT); very persistent and very bioaccumulative (vPvB); endocrine disruptors; or, in specific cases, respiratory sensitizers. The Candidate List now contains more than 240 entries and continues to grow, so testing programs must be reviewed after each ECHA update.
Testing Samples
REACH testing is typically performed on homogeneous materials, meaning materials that cannot be mechanically disjointed into different substances. Test results are reported in mg/kg per material, and the 0.1% w/w SVHC threshold corresponds to 1,000 mg/kg.
Polymeric Materials and Plastics
Plastics, rubbers, elastomers, foams, and polymer films are among the most frequently tested sample types because they commonly contain plasticizers, flame retardants, stabilizers, and processing additives. Typical analytes include phthalates, short-chain and medium-chain chlorinated paraffins (SCCP/MCCP), brominated flame retardants, bisphenols, and cyclic siloxanes. Sample preparation generally involves cryogenic milling followed by solvent extraction or dissolution prior to instrumental analysis.
Metals and Alloys
Metals, metal coatings, welds, solder, and battery components are tested for restricted elemental contaminants such as lead, cadmium, chromium VI, nickel, arsenic, and cobalt compounds. Digestion with concentrated acids (for example, nitric, hydrochloric, or hydrofluoric acid mixtures) under microwave heating is used to bring the elements into solution for spectrometric quantification.
Textiles, Leather, and Footwear
Fabrics, yarns, coatings on textiles, leather, and footwear components are analyzed for azo dyes that release restricted aromatic amines, formaldehyde, chromium VI, pentachlorophenol, nonylphenol ethoxylates, per- and polyfluoroalkyl substances (PFAS), dimethylfumarate, and phthalates in printed motifs or plasticized parts. Reference methods include the EN ISO 14362 series for azo colorants and EN ISO 17075 for chromium VI in leather.
Electrical and Electronic Products
Cables, connectors, housings, printed circuit boards, and batteries are tested for SVHC groups such as phthalates, flame retardants, borates, and lead compounds, in addition to the overlapping requirements of the RoHS directive. The IEC 62321 series provides widely applied procedures for screening and confirmatory determination of substances in electrical and electronic products.
Coatings, Inks, Adhesives, and Chemical Mixtures
Paints, varnishes, printing inks, adhesives, sealants, lubricants, and cleaning preparations are tested both as supplied mixtures and as cured films. Common analytes include solvents, phthalates, organotin compounds, isocyanates, formaldehyde releasers, and PFAS-based surfactants. Testing of mixtures is often performed in parallel with safety data sheet and registration dossier verification.
Testing Items
Testing programs are generally divided into two scopes: full SVHC Candidate List screening and targeted determination of Annex XVII restricted substances. Accredited third-party laboratories typically require 10 to 30 grams of each homogeneous material for a full SVHC screen.
SVHC Candidate List Screening
Full screening covers all entries on the current ECHA Candidate List, which includes more than 240 substances across the following principal chemical groups:
- Phthalate esters: DEHP, DBP, DIBP, BBP, DINCH-related impurities, and longer-chain phthalates.
- Bisphenols and phenolic compounds: bisphenol A, bisphenol S, 4-tert-butylphenol, and nonylphenol.
- Polycyclic aromatic hydrocarbons (PAHs) and mineral-oil-derived contaminants.
- Flame retardants: decaBDE, HBCDD, TBBPA, and organophosphate flame retardants such as TCEP and TCPP.
- Per- and polyfluoroalkyl substances (PFAS): PFOA, PFNA, PFHxS, PFBS, and related compounds.
- Cyclic siloxanes: D4, D5, and D6.
- Aromatic amines and anilines, including 4,4'-methylenedianiline and o-anisidine.
- Metals and organometallic compounds: lead compounds, cadmium compounds, cobalt salts, and arsenic compounds.
- Reprotoxic solvents and intermediates such as DEHA, DMF, and glycol ethers.
Annex XVII Restricted Substances
Targeted testing verifies compliance with specific restriction entries. Frequently requested items and limits include:
- Phthalates (DEHP, DBP, BBP, DIBP): 0.1% w/w individually or in sum in plasticized materials of consumer articles (Entries 51 and 52).
- Cadmium and its compounds: 0.01% by weight in plastics and paints (Entry 23).
- Lead and its compounds: 0.05% in consumer articles that can be mouthed or handled (Entry 63).
- Eight regulated PAHs: 1 mg/kg in rubber or plastic articles with skin or oral contact, and 0.5 mg/kg in toys and childcare articles (Entry 50).
- Nickel release: 0.2 µg/cm²/week for piercing assemblies and 0.5 µg/cm²/week for prolonged skin-contact items (Entry 27).
- Chromium VI: 3 mg/kg in leather articles and articles containing leather parts (Entry 47).
- Formaldehyde: 30 mg/kg in textiles and leather articles in direct prolonged skin contact, and 300 mg/kg for certain interior articles such as upholstery and mattresses (Entry 72).
- PFOA, its salts, and PFOA-related compounds: 0.025 mg/kg and 1 mg/kg respectively (Entry 68).
- Nonylphenol and nonylphenol ethoxylates: 0.1% in textiles and certain cleaning products (Entries 46a and 46b).
- Azodyes releasing restricted carcinogenic amines: 30 mg/kg per amine (Entry 43).
Because restriction entries are amended regularly, the applicable version of Annex XVII at the time of placing on the market must always be confirmed before finalizing a test plan.
Testing Methods
The analytical workflow consists of sample homogenization, extraction or digestion, instrumental quantification, and evaluation against regulatory thresholds. Method selection depends on the substance class, matrix, and required detection limit. For SVHC screening, the laboratory reporting limit should be well below 1,000 mg/kg, typically in the range of 10 to 100 mg/kg, so that a clear pass or fail decision against the 0.1% w/w threshold is possible.
Chromatographic and Spectrometric Techniques
- GC-MS and GC-MS/MS: determination of phthalates, PAHs, siloxanes, chlorinated paraffins, organotin compounds, solvents, and restricted amines after solvent extraction, with reference to procedures such as EN 14372, IEC 62321-8, EN ISO 14362, and EPA-style extraction protocols.
- HPLC and LC-MS/MS: determination of PFAS, bisphenols, HBCDD, disperse dyes, and thermally labile substances that are not suitable for GC analysis.
- ICP-OES, ICP-MS, and AAS: total elemental determination of lead, cadmium, chromium, nickel, arsenic, antimony, and cobalt after acid digestion.
- UV-Vis spectrophotometry: formaldehyde by the acetylacetone method (EN ISO 14184-1 for textiles and EN ISO 17226-1 for leather), chromium VI by diphenylcarbazide colorimetry (EN ISO 17075-1), and nickel artificial sweat release per EN 1811 with EN 12472 pre-treatment for coated items.
- X-ray fluorescence (XRF): rapid non-destructive screening of elemental content in polymers and metals, commonly applied per IEC 62321-3-1 before confirmatory wet-chemical testing.
- Combustion ion chromatography (CIC): screening of total organofluorine as an indicator of PFAS content in coatings, textiles, and paper-based materials.
Quality Assurance and Reporting
Validated methods should incorporate procedural blanks, matrix spikes, certified reference materials where available, and replicate determinations to demonstrate accuracy and precision. Test reports issued by accredited third-party laboratories state the results in mg/kg, the analytical method used, the reporting limit for each analyte, and a pass or fail conclusion against the relevant SVHC threshold or Annex XVII limit. Standard turnaround time for a full SVHC screen is typically five to ten working days.
Applications
REACH substance determination supports product compliance and risk management throughout the supply chain. Typical applications include:
- Market access verification for articles exported to the European Union, including support of importer and retailer documentation requests.
- Generation of data for Article 33 communication, consumer information responses, and SCIP database notifications.
- Response to market surveillance authority inquiries and enforcement sampling campaigns conducted by EU member states.
- Supplier qualification and incoming material control programs in electronics, toy, textile, footwear, jewelry, automotive, furniture, packaging, and hardware supply chains.
- Product development support, including substitution of SVHC-containing additives and reformulation of coatings, adhesives, and polymer compounds.
- Due diligence documentation for tenders, eco-label applications, and corporate sustainability reporting.
Even where no explicit test obligation exists for articles, analytical data is the most defensible evidence for demonstrating that a product does not contain SVHCs above 0.1% w/w or restricted substances above Annex XVII limits.
FAQ
What is the difference between REACH SVHC testing and RoHS testing?
REACH testing covers the full SVHC Candidate List and Annex XVII restrictions that apply to virtually all consumer and industrial articles, with SVHC results evaluated against the 0.1% w/w communication threshold. RoHS testing covers a fixed list of ten restricted substance groups in electrical and electronic equipment with maximum concentration values of 0.1% or 0.01%. The two regimes overlap for items such as phthalates and lead, but the scope, legal basis, and reporting obligations are different, and most electrical products require both assessments.
Is REACH testing legally mandatory for articles?
The regulation does not impose a universal testing obligation, but it does require accurate knowledge of SVHC content in order to meet communication, notification, and restriction duties. Importers and EU manufacturers who claim an article contains no SVHC above 0.1% w/w must be able to substantiate that claim, and laboratory determination is the accepted basis for such declarations. Enforcement authorities routinely request test reports during market surveillance checks.
How much sample is needed and what does the 0.1% w/w threshold mean?
A full SVHC screen typically requires 10 to 30 grams of each homogeneous material, while targeted single-item tests may require 2 to 10 grams. The 0.1% w/w threshold equals 1,000 mg/kg and is assessed per homogeneous material for the most conservative compliance approach, although legal obligations formally attach to the article as defined in ECHA guidance on requirements for substances in articles.
How often should REACH testing be repeated?
Testing should be refreshed whenever ECHA updates the Candidate List, whenever a material, formulation, or supplier changes, and at a minimum on an annual basis for continuing production programs. A documented material change control process combined with periodic verification testing is the standard industry practice.
How long does REACH substance determination take?
A full Candidate List screen at an accredited third-party laboratory generally takes five to ten working days after sample receipt, while targeted Annex XVII tests such as nickel release or formaldehyde may take three to seven working days. Expedited services can shorten turnaround when project schedules require it.
Which product categories are most frequently tested?
The highest testing volumes are seen in consumer electronics and accessories, toys and childcare articles, textiles, apparel, footwear, jewelry and fashion accessories, plastic and rubber household goods, sporting goods, tools, automotive interior components, and packaging materials, since these categories combine high SVHC occurrence probability with intensive market surveillance.
Why Choose ZKGX?
- State-of-the-art analytical equipment
- Highly qualified scientific team
- Fast turnaround time
- Competitive pricing